ELECTRICAL CONNECTIONS AND PROGRAMMING
⚠ Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
The control panel is powered at 230 V AC.
The control devices arepowered at 24 V AC.
Use DIP switches to set functions and the trimmer for adjustments.
All connections are quick-fuse protected.
FUSE TABLE
- Line
- Accessories
Description of parts
1.
Transformer
2.
TL trimmer for adjusting the operating time
3.
TCA trimmer for adjusting the automatic closing
4.
Radio-frequency card slot
5.
Connection terminals
6.
Transformer terminals
7.
Antenna connection terminals
6
9
8
ZC5
5 A-F
1 A-F
1
12
10
2
3
7
5
8.
Line fuse
9.
Accessories fuse
10.
Code-memorizing button
11.
Function-selector dip-switch
12.
Condenser
11
4
N.B.: Fixed motor torque: keep the
shown faston set to position 4.