 The cabinet should be installed with the inspection hatch on the most accessible side to make any adjusting easier.
Place the cabinet onto the anchoring plate and fasten it using nuts and washers.
M12 UNI 5588 nut
Washer
To change the rotation at a later date, request the documentation from your local retailer or contact Came in your Country (see the
last page or visit www.came.com)
Entry side
Entry side
LEFT barrier
RIGHT barrier
Internal zone
Internal zone
Calculate the length of the boom by using the passage width as a guide. Cut off any excess.
Boom length
230 mm
Passage width (2,500 mm max.)
30 mm
A
B
The G2500 barrier is supplied with a spring calibrated for
booms longer than 1.8 m A.
For booms shorter than 1.8 m, modify the spring hook as
shown in the figure B.
Once this procedure is finished, lock the gearmotor back into
place.