- Press the emergency stop button (D) in case of emergency
Before use, check that the on / off switch is working correctly by turning the machine on and off.
Restart in case of power failure.
The machine turns off automatically in the event of a power failure, accidental removal of the plug or
if a fuse is triggered. Press the green button on the switch to restart the machine.
End of a task:
- Reposition the splitting wedge at the lowest position.
- Release one of the control arms
- Turn off the machine and unplug the plug
- Tighten the bleed screw
- Follow the maintenance instructions
Fig. 9
5- Electrical requirements
With a 230V~ 50Hz motor, the log splitter should be connected to standard 230V10% (50Hz1Hz).
The electrical supply must be fitted with protection devices of under-voltage, over-voltage, and
over-current as well as a residual current device (RCD), which maximum residual current rated at
0.03A.
Electrical connection rubber cables must comply with EN60245 which are always marked with
H07RN, and with cross section greater than 1.5mm
Wiring and Plumbing diagrams