INITIAL OPERATION
Proceed cautiously and calmly. Take a lot of time over the basic settings.
The time required for the initial setting can be up to 30 mins. A second
person may be required to help so that changes to the controller can be
made more simply (Power OFF or ON).
1. Completely connect up the controller and drive including the safety
inputs.
2. Set all dip switches to the factory setting.
3. Set the limit switches (see limit switch setting).
4. Connect the drive to the mains power network. The lighting on the
drive lights up. (Only BAS300K).
5. The hand transmitters are ready programmed (only BAS300K).
6. Set the "OPEN" "CLOSED" potentiometer to about 30%. In the case
of very heavy doors somewhat higher. Fit the drive cover (only
BAS300K)
7. Manually move the door to a half open position and interlock the
drive.
8. Press the start button on the drive (only BAS300K) or press the
programmed hand transmitter. If the door closes instead of opens
the motor is incorrectly wired. The terminals on the controller must
then be exchanged (brown/black). The cables are exchanged in
which the capacitor is also connected. They determine the turning
direction of the motors. Then repeat to make sure that the complete
cycle takes place.
9. Test a complete cycle and on the basis of this data set different,
better values and repeat the procedure.
10. The operating modes (dip switches) should only be changed if the
end positions and the force have already been set.
11. Once all settings have been made check the function of the
photocells, buttons, flashing lights, hand transmitter, accessories etc.
If you would like automatic closing you should now change the dip
switch setting.
12. Demonstrate to all those people, who will have to operate the door,
the movement sequence of the door, how the safety functions work
and how the drive can be actuated by hand.
CHECKS
Carry out a basic functional test on the drive and accessories. Hand
over to the customer the page entitled "User Information", demonstrate
the proper operation and use of the drive as well as showing them any
potential hazards.
MAINTENANCE
The following steps should be carried out at least every 6 months:
• Checking the regulation of the motor torque.
• Check the rollers and guide rails on the door. Carry out cleaning and
lubrication as necessary.
• Functional check of the interlock release system.
• Functional check of the safety equipment.
REPAIRS
The authorized Service Centres are responsible for repair work.
709304D-GB
TECHNICAL DATA
Model
Supply voltage
Frequency
Nominal power
Max. power
Max. torque
Capacitor
Thermal protection
Motor speed
Temperature
Operating frequency, cycles/hr
Weight
Type of protection
Max. door width (m), 1 motor
Max. door height (m), 1 motor
Max. door area (m
Max. door width (m), 2 motors
Max. door height (m), 2 motors
Max. door area (m
The undersigned, hereby declare that the equipment specified, and all accessories,
conforms to the Directives and Standards stated.
Model:................................................................................................................BAS300K
EN55014, EN61000-3, EN61000-4, ETS 300 683, EN 300 220-3, EN60335-1, and
EN60335-2-95
89/336/EEC
73/23/EEC
1999/5/EC
A power door operator, in combination with a door must be installed and maintained
according to all the Manufacturer's instructions, to meet the provisions of Machinery
Directive, 89/392/EEC.
B. P. Kelkhoff
Manager, Regulatory Affairs
THE CHAMBERLAIN GROUP, INC.
Elmhurst, IL 60126
USA
May, 2004
© Chamberlain GmbH, 2004
BAS300K
230Volt
50Hz
250W
400W
350Nm
10µF
140
O
C
1400 rpm
-20 to + 55
20
approx. 9kg
IP44
3
3
2
), 1 motor
8
5
3
2
), 2 motor
14
D e c l a r a t i o n o f C o n f o r m i t y
D e c l a r a t i o n o f I n c o r p o r a t i o n
Manager, Reg. Affairs
O
C
Barbara P. Kelkhoff