This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of the
purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information.
Board Selector Dial
Factory Setting is C2*
T
TS
E2
FSTS
D1
DIAG
C2
OPTN
B2
PROG
*See installation manual for full description
of modes.
Remote Controls
Built in 3-channel, Security
2.0
radio receiver
TM
that allows you to add up to 90 remote control
devices and up to 30 keyless entry devices.
MAS Programming (Maintenance Alert System)
1. The MAS assists the installing dealer in setting
up a routine maintenance program. Once
programmed, the MAS notifies the end user
(with a flashing LED on the 3 button station)
when a preset number of cycles/months has
elapsed and scheduled maintenance is due.
2. Close the Door.
T
TS
E2
FSTS
3. Turn the selector dial
D1
DIAG
to Program.
C2
OPTN
PROG
B2
MAS
4. Press and release the MAS button.
OPEN
D20
CLOSE
5. Press the STOP button once
D21
to clear the MAS counter.
STOP
D13
for the model T door operator
CONTROL WIRING
20 AWG or greater
USE COPPER WIRE ONLY
1
2
3
4
5
6
7
8
9 10 11 12 13
11
8
Maintenance Alert LED
6. Press the OPEN button once for
OPEN
D20
every 5,000 Cycles increments.
Press the CLOSE button once for
CLOSE
D21
every 3 Month increments.
STOP
D13
Press the STOP button once to
Clear the MAS Setting.
MAS
7. Press the MAS button to
complete the programming.
The on board LED will flash back
OPEN
D20
the programmed settings. The
OPEN LED will flash once for every
CLOSE
D21
5,000 cycles. The CLOSE LED will
STOP
D13
flash once for every 3 months.
T
TS
8. Turn the selector dial back
E2
FSTS
to the desired wiring type.
D1
DIAG
C2
OPTN
B2
PROG
LiftMaster Monitored Entrapment Protection (LMEP)
is required for most programmable settings.
14
Thru-Beam Photoelectric Sensors (Shown)
White
11
White/Black
9
Follow ALL national and local electrical codes
10
Push and Release to Open
7
4
(without Mid Stop programming)
Hold
Push and
to Close
6
4
Push and Release to Stop
5
4
Timer-to-Close Programming
Timer automatically closes door after a preset time.
1. Close the Door.
T
TS
E2
FSTS
D1
DIAG
C2
2. Turn selector to PROG.
OPTN
B2
PROG
3. Press and release the TIMER button.
MRT
MID
TIMER
4. Press and release the STOP button to clear the timer.
5. Press and release the OPEN button once for every 1 second.
Press and release the CLOSE button once for every 15 seconds.
Example:
Push CLOSE + Push OPEN + Push OPEN = 17 seconds total
(15 seconds) (1 second)
(1 second)
6. Press and release the TIMER button to complete programming.
The OPEN LED will flash once for every 1 sec.
MRT
MID
TIMER
The CLOSE LED will flash once for every 15 sec.
7. Turn selector to T, TS or FSTS wiring types.
E2
D1
NOTE: Must have at least one LiftMaster Monitored
C2
Entrapment Protection (LMEP) device installed.
B2
NEVER run
Control wiring
in same conduit
as the Power wiring!
OPEN
CLOSE
STOP
6" max.
above floor
OPEN Mid Stop Programming
OPEN
D20
The mid stop feature is to open the door to a preset point prior to the fully open position.
CLOSE
D21
1. Close the Door.
STOP
D13
2. Turn selector to PROG.
OPEN
D20
CLOSE
D21
3. Press and release the MID button.
STOP
MRT
MID
D13
4. Press the OPEN button, wait until the door reaches the desired
OPEN
D20
mid stop height, then press and release the STOP button.
CLOSE
D21
5. Press and release the MID button to complete programming.
STOP
D13
MRT
MID
T TS
FSTS
DIAG
OPTN
6. Turn selector back to selected wiring type.
PROG
LOGIC 5
WARNING: This product can expose you to chemicals
including lead, which are known to the State of California to
cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Edge Sensor
T
TS
E2
FSTS
D1
DIAG
C2
OPTN
PROG
B2
TIMER
OPEN
D20
CLOSE
D21
STOP
D13
TIMER
T
TS
E2
FSTS
D1
DIAG
C2
OPTN
B2
PROG

Publicité

loading

Sommaire des Matières pour Chamberlain Elite Serie Logic 5 T

  • Page 1 QuickStart LOGIC 5 for the model T door operator WARNING: This product can expose you to chemicals This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of the including lead, which are known to the State of California to purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use.
  • Page 2 QuickStart for the model T door operator a d e Front Idler c k e B r a IMPORTANT: This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use.
  • Page 3 LOGIC 5 AVERTISSEMENT : Ce produit peut vous exposer Ce démarrage rapide est destiné à mettre en valeur une installation typique. Ces instructions ne se veulent pas exhaustives. C'est parce que chaque application est unique qu'il incombe à l'acheteur, au concepteur, à l'installateur et à l'utilisateur final de s'assurer que le système complet de la porte est sans danger dans le cadre prévu de son utilisation.
  • Page 4 Lorsque l'enclenchement est correctement réglé, il doit être généralement possible d'arrêter la porte à la main pendant son déplacement. Réinstallez la goupille fendue à la fin de l'opération. Instructions de programmation de radio à l'intérieur du couvercle du système de fermeture. © 2014, The Chamberlain Group, Inc. Dispositif All Rights Reserved...