Axovia 220B
This product is a drive for a hinged gate on a residential prop-
erty as defined in standard EN 60335-2-103, with which it is
compliant. The main purpose of these instructions is to satisfy
the requirements of the aforementioned standard and to en-
sure the safety of equipment and persons.
WARNING
Any use of this product outside the scope application de-
scribed in these instructions is prohibited (see "Field of
application" paragraph in the installation manual).
The use of any accessory or any component not recom-
mended by Somfy is prohibited, on safety grounds.
Any failure to comply with the instructions given in this guide
shall exclude Somfy from all liability and invalidate the Somfy
warranty.
If in any doubt when installing the motorisation, or to find out
more, go to the website www.somfy.com.
The instructions may be modified if and when there is a change
to the standards or to the motorisation.
1.3. Preliminary checks
1.3.1. Installation environment
ATTENTION
Do not spray water onto the motorisation.
Do not install the motorisation in an explosive environ-
ment.
Check that the temperature range marked on the motori-
sation is suited to the installation location.
1.3.2. Condition of the gate to be motorised
Only motorise a gate which has been correctly installed and is
in good working order.
Before installing the motorisation, check that:
• the gate is in good mechanical condition
• the gate is stable regardless of its position
• the structures supporting the gate allow the drive to be
fixed securely. Strengthen these if necessary.
• the gate can be opened and closed properly using a force
of less than 150 N.
1.4. Risk prevention
WARNING
Risk prevention - motorising a hinged gate for residen-
tial use
Ensure that any danger zones (crushing, cutting, trapping)
between the motorised section and the surrounding fixed
sections created by the opening of the motorised section
are avoided or indicated on the installation.
Permanently affix the crushing warning labels near to any
fixed control devices, and so that they are clearly visible
to the user.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Risk zones: measures to be taken to eliminate risks.
RISK
SOLUTION
ZONE 1
Obstacle detection built into the
drive. Obstacle detection must be
Risk of crushing dur-
confirmed as being compliant with
ing closing
Appendix A of standard EN 12 453.
For operation with automatic clos-
ing, install photoelectric cells.
ZONE 2
Obstacle detection built into the
drive. Obstacle detection must be
Risk of cutting or
confirmed as being compliant with
crushing
between
Appendix A of standard EN 12 453.
the gate leaf and any
adjoining fixed sec-
Protection via safety distances (see
tions
figure 1)
ZONE 3
Obstacle detection built into the
drive. Obstacle detection must be
Risk of crushing with
confirmed as being compliant with
an adjoining fixed
Appendix A of standard EN 12 453.
section upon open-
ing
Mechanical protection (see figure 2)
Remove any gap ≥ 8 mm or ≤ 25
mm
ZONE 4
Obstacle detection built into the
drive. Obstacle detection must be
Risk of crushing be-
confirmed as being compliant with
tween the secondary
Appendix A of standard EN 12 453.
edges and adjoining
fixed sections
Remove any gap ≥ 8 mm or ≤ 50
mm
ZONE 5
Obstacle detection built into the
drive. Obstacle detection must be
Risk of cutting be-
confirmed as being compliant with
tween the arms, the
Appendix A of standard EN 12 453.
arms and the motor
cover.
Protection via safety distances (see
figure 1)
Risk of crushing be-
tween the arms and
gate
No protection is required if the gate has continuous control
or if the danger zone is more than 2.5 m above ground or any
other permanent access level.
Figure 1 - Safety distance
EN
Zone 3
Zone 2
Zone 1
Zone 5
Zone 4
2