Use
Type of gas used
LIQUIFIED
PETROLEUM GAS
(Butane)
G30
LIQUIFIED
PETROLEUM GAS
(Propane)
G31
NATURAL GAS
(Methane/
Nitrogen)
G2.350
Burner
Auxiliary
Semi-rapid
Triple Ring
Operation
Burner operation
Push and turn the control knob around to the spark zone ( ) of the control until the gas lights.
Reduce the gas level to suit the cooking required.
If the gas fails to light first time, please try again.
After cooking, switch off the burner by turning the control knob back to the off position ( ).
CAUTION: If there is no electric current you can light the burners with a piezo
The burners can only be lit with safety thermocouples when the
Do not use cooking vessels on the hob that overlap the edges of the pan supports.
WARNING: Always switch off the electricity and gas supply before performing
maintenance work. In the event of a fault, contact customer services at the end of
Type of
Injector
burner
marking
Auxiliary
0.50mm
Semi-Rapid
0.63mm
Wok
0.84mm
0.51 mm
Auxiliary
0.69 mm
Semi-Rapid
0.88 mm
Wok
Auxiliary
1.0mm
Semi-Rapid
1.30mm
Wok
1.70mm
Minimum Pan Diameter (cm)
≥ 10
≥ 16
≥ 24
electric spark gas ignitor.
knob is on MAXIMUM.
the care and maintenance section.
Rated
Rated
thermal
consumption
flow
rate kW
1
73 g/h
1.75
127 g/h
3
218 g/h
71 g/h
1
125 g/h
1.75
214 g/h
3
1
132 lt/h
1.75
232 lt/h
3
397 lt/h
Maximum Pan Diameter (cm)
Reduced
heat
pressure
capacity
kW
0.28
0.49
0.75
0.28
0.49
0.75
0.28
0.49
0.75
≤ 14
≤ 20
≤ 28
30
Gas
rating
(mbar)
37
37
13

Publicité