Use
Type of gas used
LIQUIFIED
PETROLEUM GAS
(Butane)
G30
LIQUIFIED
PETROLEUM GAS
(Propane)
G31
NATURAL GAS
(Methane/
Nitrogen)
G2.350
Burner
Auxiliary
Semi-rapid
Triple Ring
Operation
Burner operation
•
Push and turn the control knob around to the spark zone ( ) of the control until the gas lights.
•
Reduce the gas level to suit the cooking required.
•
If the gas fails to light first time, please try again.
•
After cooking, switch off the burner by turning the control knob back to the off position ( ).
CAUTION: If there is no electric current you can light the burners with a piezo
The burners can only be lit with safety thermocouples when the
Do not use cooking vessels on the hob that overlap the edges of the pan supports.
WARNING: Always switch off the electricity and gas supply before performing
maintenance work. In the event of a fault, contact customer services at the end of
Type of
Injector
burner
marking
Auxiliary
0.50mm
Semi-Rapid
0.63mm
Wok
0.84mm
0.51 mm
Auxiliary
0.69 mm
Semi-Rapid
0.88 mm
Wok
Auxiliary
1.0mm
Semi-Rapid
1.30mm
Wok
1.70mm
Minimum Pan Diameter (cm)
≥ 10
≥ 16
≥ 24
electric spark gas ignitor.
knob is on MAXIMUM.
the care and maintenance section.
Rated
Rated
thermal
consumption
flow
rate kW
1
73 g/h
1.75
127 g/h
3
218 g/h
71 g/h
1
125 g/h
1.75
214 g/h
3
1
132 lt/h
1.75
232 lt/h
3
397 lt/h
Maximum Pan Diameter (cm)
Reduced
heat
pressure
capacity
kW
0.28
0.49
0.75
0.28
0.49
0.75
0.28
0.49
0.75
≤ 14
≤ 20
≤ 28
30
Gas
rating
(mbar)
37
37
13