Télécharger Imprimer la page

Cooke & Lewis CLGH60ALL Mode D'emploi page 29

Publicité

Use
EN
Before you start
Switch on the appliance at the mains consumer unit. The appliance is ready for use.
WARNING: Read the instructions before using the appliance.
Function & Settings
Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out.
Auto ignition.
Injector Table
Gas Category
GB & IE: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
FR: II2E+3+ (G20 20 mbar, G25 25 mbar, G30 28-30 mbar, G31 37 mbar)
ES & PT: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
RO: II2H3B/P (G20 20 mbar, G30 30 mbar, G31 30 mbar)
PL: II2ELS3B/P (G20 20 mbar, G2.350 13 mbar, G30 37 mbar, G31 37 mbar)
Type of gas used
NATURAL GAS
(Methane)
G20
NATURAL GAS
(Methane/
Nitrogen)
G25
LIQUIFIED
PETROLEUM GAS
(Butane)
G30
Type of
Injector
burner
marking
Auxiliary
0.74 mm
Semi-Rapid
0.98 mm
Wok
1.24 mm
Auxiliary
0.74 mm
Semi-Rapid
0.98 mm
Wok
1.24 mm
Auxiliary
0.51 mm
Semi-Rapid
0.69 mm
Wok
0.88 mm
Rated
Rated
thermal
consumption
flow
rate kW
1
95 lt/h
1.75
167 lt/h
3
286 lt/h
1
110 It/h
1.75
194 It/h
3
332 It/h
1
73 g/h
1.75
127 g/h
3
218 g/h
29
Reduced
Gas
heat
pressure
capacity
rating
kW
(mbar)
0.28
20
0.49
0.75
0.28
25
0.49
0.75
0.28
0.49
28-30