Wall Mounting Bracket When Replacing An Appliance; Installation With Offset Tiles; Pivoting Appliance Cover; Operation With Preheated Water - Stiebel Eltron DEL 18 Plus Utilisation Et Installation

Chauffe-eau instantané confort à régulation électronique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INsTALLATIoN
Alternative installation methods
f Cut open the lower back panel section.
f
f Fit the lower back panel section by bending it out at the sides
f
and guiding it over the pipes.
f Insert the connection pieces into the lower back panel sec-
f
tion from behind.
f Click the lower back panel section into place.
f
f Secure the lower back panel section with a screw.
f
13.9 Wall mounting bracket when replacing an
appliance
An existing STIEBEL ELTRON wall mounting bracket may be used
when replacing appliances (except the DHF instantaneous water
heater), as long as the fixing screw is in the lower right position.
Replacing a DHF instantaneous water heater
f Reposition the fixing screw on the wall mounting bracket (the
f
fixing screw has a self-tapping thread).
f Rotate the wall mounting bracket 180° and mount it on the
f
wall (the DHF logo is then turned towards you).

13.10 Installation with offset tiles

20
2
1
1 Minimum contact area of the appliance
2 Maximum tile offset
f Adjust the wall clearance. Lock the back panel in place using
f
the fixing toggle (turn 90° clockwise).
www.stiebel-eltron.com

13.11 Pivoting appliance cover

The appliance cover should be turned round for undersink in-
stallation.
f Remove the programming unit from the appliance cover by
f
pressing the locking hooks and removing the programming
unit.
f Turn the appliance cover (not the appliance) the other way
f
up and refit the programming unit. Push the programming
unit home in parallel until all locking tabs engage. When
engaging the locking tabs, apply counter pressure by pushing
against the appliance cover from the inside.
WARNING Electrocution
All 4 locking tabs on the programming unit must click into
place. The locking tabs must be complete and undam-
aged. If the programming unit is not inserted correctly,
user protection against contact with live components
cannot be ensured.
f Insert the connecting cable plug of the programming unit
f
into the PCB (see chapter "Commissioning / Initial start-up").
f Hook the appliance cover in at the bottom. Pivot the appli-
f
ance cover up to the back panel.
f Secure the appliance cover.
f
f Fit the cover onto the appliance cover.
f

13.12 Operation with preheated water

You can restrict the maximum inlet temperature by installing a
central thermostatic valve.
DEL Plus |
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Del 21 plusDel 24 plusDel 27 plus

Table des Matières