Télécharger Imprimer la page

BFT GIOTTO BT B ULTRA 36 Instructions D'utilisation Et D'installation page 35

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
Parameter
min.
max.
20
80
Op. speed
20
80
cl speed
0
250
aintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
(***)Reference for universal handheld programmer.
(****) Modifying the "motor type" logic involves automatic modification of this channel.
TABLE "B" - LOGIC - (LOGIC)
Logic
Definition
Spring type or bar
otor type
length
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
OVE NT
Pre-alarm
PRE-ALAR
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
*IBL TCA
Block pulses during
IBL CLOSE
closing
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Default
Personal
45
Speed during opening
45
Speed during closing
Programming number of
operations for maintenance
0
Cross out
Default
setting
used
0
1
1
0
1
 
1
0
0
 
1
0
1
 
1
2
0
0
 
1
0
1
0
 
2
0
1
 
1
0
0
 
TCA
1
0
0
 
1
0
0
 
1
0
1
4
72
2
3
4
5
6
6
74
7
8
ENGLISH
Definition
Description
Running speed during opening [%]
Sets the running speed that the barrier must reach during opening, as a
percentage of the maximum speed the barrier can reach ( ****).
Running speed during closing [%]
Sets the running speed that the barrier must reach during closing, as a
percentage of the maximum speed the barrier can reach ( ****).
Allows you to set a number of operations after which the need for main-
tenance will be reported on the AUX output configured as Maintenance
threshold
or Flashing Light and Maintenance .
[in hundreds]
Short bars 20-45, generally standard spring
Long bars 45-60, generally XL spring
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 1 second after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I, Ped
operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I, Ped
operate with 2-step logic. Movement
reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman
mode is enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse from inputs configured as Start E, Start I has effect during opening.
Pulse from inputs configured as Start E, Start I has no effect during opening.
Pulse from inputs configured as Start E, Start I has effect during TCA pause.
Pulse from inputs configured as Start E, Start I has no effect during TCA pause.
Pulse from inputs configured as Start E, Start I has effect during closing.
Pulse from inputs configured as Start E, Start I has no effect during closing.
Standard operating mode (left barrier).
Opens in other direction to standard operating mode (right barrier).
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2.
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
GIOTTO BT B ULTRA 36 -
4 STEP
OPENS
STOPS
CLOSES
OPENS
35

Publicité

loading