IX - TECHNICAL FEATURES
Cristalys and Opalys clocks comply with the electromagnetic compatibility directive 2004/108/CE & DBT
2006/95/CE. This is a Class A product. In a domestic environment this product may cause radio frequency
interference, in which case the user may be required to take adequate measures.
This product is suitable for installation in a residential, commercial or light industrial environment. It
complies with the European standards in force.
The NTP server must have a transmission (Poll) period of less than 128 seconds
Long term accuracy of the clock's time base without SNTP synchronisation (or 0.2 s/day at 20°C with HLCD
clock calibrated) and short-term accuracy of 200 ms with SNTP synchronisation (jitter)
Synchronisation: complying with RFC2030 (SNTP V4) and Multicast address
Network connection: RJ45 Ethernet, 10 base-T
Power supply: PoE (power over Ethernet), Cristalys 45 mA, Opalys 140 mA
Operating temperatures : from 0 °C to +50 °C.
Humidity : 80 % at 40 °C
Protection : IP 40
Weight : 1,4 Kg.
Dimensions :
Display :
AM and PM for
12hr mode
.
321
269
.
.
.
.
NTP reception indicator
(pictogram flashing)
41