10.1. Application and Operation
The Balloon Material must
be kept out of the reach of
children as it is a potential
source of danger. As an alternative to
the VOLCANO Balloon, only use
heat-resistant, food safe and odor-
free oven tubes and oven bags.
10.1.1. Filling the Filling Chamber
Remove the entire Filling Chamber In-
sert and fill the Chamber with the de-
sired amount of ground plant material.
Fill Filling Chamber
Fit in the Filling Chamber Insert and
use the pin to lower the Screen Unit so
that the content of the Filling Chamber
is loosely fixed between the Screens.
10. S O L I D VA LV E
Insert Filling Chamber Insert
Make sure that the Filling Chamber
Disc sits properly in the Filling Cham-
ber. It must touch the top edge of the
Filling Chamber Cylinder made of
stainless steel.
sults, we recommend to clean the
Screens after each vaporization cycle
with the enclosed Cleaning Brush.
Put the Filling Chhamber on the hot air
max. 10 mm
outlet of the Hot Air Generator. Switch
on the air pump. To do so, press the
min. 1 mm
green button/switch labeled "AIR". The
Filling Chamber as well as the vapor-
ization material must be preheated for
a couple of seconds before the aromas
and fragrances will start to vaporize.
74
approx. 1 mm
Take care that the Screens are
not obstructed with plant ma-
terial. To guarantee optimal re-