40mA
400mA
4A
20A
Resistance
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Capacity
40nF
400nF
4µF
40µF
100µF
Continuity tester
An audio signal of a continuity is generated for resistance values
less than approximately 70Ω. Moreover, for values up to 100Ω the
indication is only given in "Ω" without an audio signal.
Diode test
The maximum measuring voltage at the object is about 1.48VDC
(maximum), display resolution 1mV.
Frequency measurement / pulse-pause-ratio / pulse duration mea-
surement
10Hz –
10MHz
input sensitivity 0.3Veff from 10Hz to 1MHz
Input sensitivity 0.6Veff > 1MHz
46
All manuals and user guides at all-guides.com
±(2.0%+5dgts)
±(2.0%+5dgts)
±(2.5%+5dgts)
±(2.5%+5dgts)
±(1.2%+2dgts)
±(1.0%+2dgts)
±(1.0%+2dgts)
±(1.0%+2dgts)
±(1.2%+2dgts)
±(1.5%+2dgts)
±(3.0%+10dgts) 0.01nF
±(3.0%+5dgts)
±(3.0%+5dgts)
±(3.0%+5dgts)
±(4.0%+5dgts)
±(0.1%+3dgts)
0.01mA
40 to 400Hz
0.1mA
40 to 400Hz
0.001A
40 to 400Hz
0.01A
40 to 400Hz
0.1Ω
0.001kΩ
0.01kΩ
0.1kΩ
0.001MΩ
0.01M Ω
0.1nF
0.001µF
0.01µF
0.1µF
0.01Hz –
10kHz