Measurement tolerances
Indication of accuracy in ±(% of the measurement value read +
number of positions = digits =dgt(s)). Accuracy valid for 1 year at a
temperature of +23°C ± 5°, and at a relative air humidity of less than
80%, non-condensing. The warm-up time is 1 minute.
Measurement
range
Direct voltage
400mV
4V
40V
400V
1000V
Input impedance: 10 MΩ, apart from the 400mV range: 4000MΩ
Alternating voltage
4V
40V
400V
750V
Input impedance: 10MΩ, < 100pF
Direct current DCA (µA and mA and A)
400µA
4000µA
40mA
400mA
4A
20A
Alternating current ACA (µA and mA and A)
400µA
4000µA
All manuals and user guides at all-guides.com
Accuracy
±(0.8%+5dgts)
±(0.8%+5dgts)
±(0.8%+5dgts)
±(0.8%+5dgts)
±(1.0%+5dgts)
±(1.0%+5dgts)
±(1.0%+5dgts)
±(1.0%+5dgts)
±(1.2%+5dgts)
±(1.0%+2dgts)
±(1.0%+2dgts)
±(1.2%+3dgts)
±(1.2%+3dgts)
±(1.5%+5dgts)
±(1.5%+5dgts)
±(2.0%+5dgts)
±(2.0%+5dgts)
Resolution Frequency
0.1mV
0.001V
0.01V
0.1V
1V
0.001V
40Hz to 400Hz
0.01V
40Hz to 400Hz
0.1V
40Hz to 400Hz
1V
40Hz to 400Hz
0.1µA
1µA
0.01mA
0.1mA
0.001A
0.01A
0.1µA
40Hz to 400Hz
1µA
40 Hz to 400Hz
45