Télécharger Imprimer la page

TLV JH-B Serie Manuel D'utilisation page 14

Purgeurs de vapeur à flotteur ferme libre

Publicité

Les langues disponibles

Les langues disponibles

7. Maintenance Parts and Repair Parts
Maintenance parts and repair parts are available from TLV only in kits, as shown below.
Maintenance Kit: M
Repair Kit: R
Orifice 4
Orifice Gasket 5
Orifice Plug Gasket or
Outlet Cover Gasket 7
Float Cover 8
Screen 9
Cover Gasket 13
Connector Gasket 15
Snap Ring 16
Air Vent Case 17
Bimetal Plate 18
Air Vent Screen 19
Air Vent Valve Seat 20
Air Vent Valve Plug 21
Snap Ring 22
Drain Plug Gasket* 26
Orifice Locknut 28
Air Vent Guide Gasket 32
* Option for JH3-B, JH5RL-B, JH5RH-B
Float Replacement
8. Operational Check
A visual inspection can be carried out to aid in determining the necessity for immediate
maintenance or repair, if the trap is open to atmosphere. If the trap does not discharge to
atmosphere, use diagnostic equipment such as TLV TrapMan or TLV Pocket TrapMan (within
their pressure and temperature measurement range).
Normal:
Condensate is discharged continuously with flash steam and the sound
of flow can be heard. If there is very little condensate, there is almost no
sound of flow.
Blocked:
No condensate is discharged. The trap is quiet and makes no noise,
and the surface temperature of the trap is low.
Blowing:
Live steam continually flows from the outlet and there is a continuous
metallic sound.
Steam
Live steam is discharged through the trap outlet together with the
Leakage:
condensate and there is a high-pitched sound.
(When conducting a visual inspection, flash steam is sometimes mistaken for steam leakage. For
this reason, the use of a steam trap diagnostic instrument such as TLV TrapMan is highly
recommended.)
White jet
containing
water droplets
JH5RL-B
JH7RL-B
JH3-B
JH5RH-B
JH7RM-B
M
R
M
R
M
Replacement floats are available for all models above.
Flash Steam
̶ 13 ̶
JH7RH-B
JH7.2R-B
R
M
R
M
Live Steam Leakage
Clear, slightly
bluish jet
JH7.5R-B JH8R-B
R
M
R
M
R

Publicité

loading