Setting temperature with temperature buttons ┌ 1 ┐, ┌ 2 ┐ and┌ 3 ┐
The setpoint temperature value can be set for each channel
separately by selecting three preset temperature values (fixed
temperatures).
Factory settings:
┌ 1 ┐ = 150 °C (300 °F), ┌ 2 ┐ = 350 °C (662 °F),
┌ 3 ┐ = 380 °C (716 °F)
1. Select a channel.
Three fixed temperatures are shown in the display for
approx. 2 s.
The temperature value can now be input as long as the
temperature symbol is flashing.
2. Set the setpoint temperature value with the UP or DOWN button.
3. Keep the desired temperature button ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐
pressed for 3 seconds.
The temperature display for the corresponding temperature value
flashes during this period. The set value is saved after 3 s.
4. Release the temperature button again.
Note
Assigning a low "Setback" temperature to a temperature button
offers the possibility of manual temperature reduction when the
soldering iron is not in use.
Selecting temperature with temperature buttons ┌ 1 ┐, ┌ 2 ┐
and ┌ 3 ┐
1. Select a channel.
2. Three fixed temperatures shown in the display for approx. 2 s.
As long as the temperature symbol is flashing, the desired
temperature can be selected by pressing ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐.
6.3
Soldering
Carry out the soldering work in accordance with the Operating
Manual of your connected soldering tool.