The specified vibration value was established in ac-
cordance with a standardized testing method. It may
change according to how the electric equipment is
used and may exceed the specified value in exception-
al circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial as-
sessment of a harmful effect.
Keep the noise emissions and vibrations to a min-
imum.
• Only use appliances which are in perfect working
order.
• Service and clean the appliance regularly.
• Adapt your working style to suit the appliance.
• Do not overload the appliance.
• Have the appliance serviced whenever necessary.
• Switch the appliance off when it is not in use.
• Wear protective gloves.
8. Before putting the machine into
operation
Correctly using the device
• The high-pressure cleaner must be set on a level,
stable surface.
• It is recommended that you maintain the correct op-
erating position every time you use the machine by
placing one hand on the pistol and the other on the
lance.
• Never direct the water jet toward electrical lines or
the machine itself.
• It is normal for the pump to leak a little; this is nec-
essary to avoid damage to the pump when it is at a
standstill.
• Never use the equipment in potentially explosive ar-
eas under any circumstances!
• The operating temperature must be between +5 and
+ 50°C.
• Do not cover or modify the lance or the spray noz-
zles in any way.
• The high-pressure cleaner is designed to be used
with cold or lukewarm water (max. 50°C); higher
temperatures can damage the pump.
• Do not use water that is dirty, gritty or contains any
chemical products, as these could impair operation
and shorten the life of the equipment.
24 | GB
Assembly
Device assembly (fig. 1)
Push the handle (1) onto the fastening points at the top
of the device and secure using the two screws provid-
ed (length 25 mm)
Water supply connection (Fig. 2)
Screw the connection for the water supply (14) onto the
device. The connection for the water supply (14) fea-
tures a connection for standard hose coupling systems.
Attach the hose coupling of the supply hose (min. Ø
1/2"/ approx. 13 mm) onto the connection for the wa-
ter supply (14).
Always use an enhanced water hose with an indus-
try-standard coupling for the water supply. The length
should be at least 6.0 m. (not included in the scope
of delivery)
A backflow prevention device must be installed be-
tween the drinking water and the high-pressure clean-
er! Ask your plumbing expert about this.
Suction from open tanks/containers and natural
bodies of water
Use a special self-suction accessory (not included with
delivery / available from dealer)
With this accessory, the high-pressure cleaner can
take in water 0.5 m above the water level. This can
last about 25 to 50 seconds. Immerse the accesso-
ry's hose completely under water to drive the air out
of the hose.
Connect the accessory's hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray
gun removed until the water flows evenly out of the
high-pressure hose. If no water comes out after 25
to 50 seconds, switch off and check all connections.
Once the water is flowing, turn off the high-pressure
cleaner and connect the spray gun and spray lance
to start work.
High-pressure hose connection (Fig. 3/4)
Connect the high-pressure hose (9) to the connection
for the high-pressure hose (4). Remove the protective
cover first.
Insert the other end of the high-pressure hose (9) into
the pistol connection (8).
To remove the high-pressure hose (9), press the but-
ton (A) and pull it out.