Skyscreen Powered
7.4
Fitting the cover (optional)
➤ Proceed as shown (fig. b, page 9).
7.5
Electrical installation
The electrical power supply must be connected by a qualified electrician who
has demonstrated skill and knowledge related to the construction and opera-
tion of electrical equipment and installations and has received safety training to
identify and avoid the hazards involved.
The powered blinds are available for a connection to a 12/24 Vg power supply.
The data plate on the head rail provides important information on the specifica-
tions of the motor.
The following notes must be observed when connecting the blinds:
• Ensure cables are not damaged during installation. Routings of cables
through walls or bulkheads must be protected and insulated by appropriate
bushing, grommets or cable conduits.
• Ensure that a 12 V or 24 V stabilized power supply line is available for the
drive at the point of installation. The power supply line is suitably arranged
and protected.
• The product must be connected to the correct power supply as specified on
the product label. The motor in the product is designed to cut out when a set
current is exceeded but the supply should be fused to protect the wiring to
the product.
• Secure all cables to prevent any contact with moving parts.
• Only use power supply units and control elements recommended by the
manufacturer to prevent damage or faults during operation caused by incom-
patible electrical components.
• Control devices (e.g. switches) must be installed in visible locations.
• One regulated power supply of the required specification is required per
motor as failure to do so may cause the motor to function improperly.
• Any adjustment of set stop positions should only be made using the method
specified for the motor type to avoid damage to the motor.
➤ Connect the motor as shown in the wiring diagrams:
– Dometic radio controlled blind internal receiver (fig. c, page 10)
– Dometic radio controlled blind external receiver (fig. d, page 10)
– Manually switched blind (fig. e, page 11)
– Somfy radio controlled blind external receiver (fig. f, page 11)
– Somfy radio controlled blind internal receiver (fig. g, page 11)
EN
Installation
19