2610051827 GCM12SD 08-18.qxp_GCM12SD 9/19/18 2:52 PM Page 23
power source before performing any assem-
bly, adjustments or repairs.
Calibrating Miter Detent System
1.Engage the miter detent at the 0° position.
Loosen the miter lock knob 1/2 turn.
2.Look for four round holes in the miter scale
plate. In each hole is a screw. Use the small
end of the 6/4mm hex key or a 4mm hex key
to loosen all four screws 1 to 2 turns. This will
loosen the miter detent plate (see Figure 18).
3.Lock saw down using the head assembly lock
pin (item 43 – page 12).
4.Hold one side of a 90° combination square
against the fence and rotate the table (and
detent plate) until the side of the saw blade
is in full contact with the other side of the
square.
5.Tighten all four screws – loosen and reset the
miter scale pointer to the "0" position.
Miter Scale Pointer Adjustment
1.Rotate table to 0° position and lock in place.
2. Raise the head assembly to the full UP posi-
tion.
3. Loosen the pointer adjust screw that holds the
miter scale pointer in place (see Figure 20).
4.Position the pointer to align with the 0° line.
Tighten the screw.
.800.544.2843
Miter Detent System – Adjustment Procedure
To avoid possible injury,
disconnect
plug
www.calcert.com
15
10
20
5
25
30
0
Adjustments
from
Contacting
Fence
Pointer Adjust
Screw
Miter Scale Pointer
Screws
Detent Plate
Contacting
Blade
Set Miter
Detent at 0°
Combination
Square
0° Line
sales@calcert.com
Fig. 18
Fig. 19
Fig. 20