ROOM TEMPERATURE
This function gives a readout of
the current room temperature,
minimum
temperature values can also be
displayed. Internal switch #5
must be set to ON and a
temperature probe must be
connected for this function to
work. Note that this function is
not available during calibration.
Settings
Turn the adjustment knob one notch to the right. The maximum
value is displayed alternating with the letters "Hi".
Turn the adjustment knob one notch to the left. The current
opening is displayed.
Turn the adjustment knob one notch to the left. The minimum
value is displayed, alternating with the letters "Lo".
Note :
If you let the display flash for more than 10 seconds, the controller
resets the minimum and maximum opening values currently in memory.
In other words, the two values are reset to the current opening value. To
avoid resetting minimum and maximum values, return to the current
opening display using the adjustment knob (clockwise or
counterclockwise) before the 10 second delay has elapsed.