BEFORE CALIBRATING THE REFERENCE POINTS
When to calibrate the reference points
It is preferable to calibrate the reference points when the room
is empty because adjusting the air inlet openings will cause
drafts.
Operation of the temperature controller
In order to properly simulate the operation of the ventilation
stages, adjust all the parameters at the same value that would
be used at the first day of a new breeding.
If variable fans are used to ensure minimum ventilation, adjust
the minimum speed of the fans at the same speed that would
be used at the first day of a new breeding.
Be sure that the circuit breakers at the service panel and all
other protection devices are in a position such that the fans can
be activated.
Air inlet panel position
Install a static pressure measuring device or determine in
advance the position required at each reference point by
calculating, according to the fan airflow, the opening that will
maintain the desired air speed at the inlet.
PF-6 internal switches:
Set the lock switch to OFF in order to unlock the automatic
mode.
Using the season switch, select the season you want to
program.
20