Electrical Connection - Balluff BTL5-P/I/L/M1-M Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL5-P/I/L/M1-M _ _ _ _ -H/W(8) -S32/KA _ _ /K _ _
Magnetostrictive Linear Position Sensor – Rod Style
4
Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, BTL installed with supporting rod
4.4

Electrical Connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2.
Note the information on shielding and cable
routing on page 11.
Pin
Wire color
1
YE
Yellow
2
GY
Gray
3
PK
Pink
4
RD
Red
5
GN
Green
6
BU
Blue
7
BN
Brown
8
WH
White
1) Unassigned leads that are not used can be connected to the GND on the controller side but not to the shield.
Tab. 4-2:
Connection assignment
Init pulse
No. 1
Init pulse
No. 2
Init pulse
No. 3
Init pulse
No. 4
BTL5-I...
Output signal
Start/Stop
Fig. 4-9:
Connection scheme, bus operation
10
english
Magnet
(e.g. BTL-P-1028-15R)
-P...
+Start/Stop
(2nd edge)
(tri-state, 2nd edge)
−Start/Stop
(2nd edge)
(tri-state, 2nd edge)
Fig. 4-10: Pin assignment of S32 (view from above on BTL),
8-pin M16 circular plug
-I...
-L...
+Init
+Start/Stop
+Tor
−Init
Not used
1)
−Start/Stop
−Tor
GND
20...28 V
Not used
1)
-M...
+Start/Stop
(1st edge)
−Start/Stop
(1st edge)

Publicité