Make sure that the electrical characteris cs of building electric network follow the
technical specifica ons of the oven which can be found on the iden fica on plate
located on the back panel and in the electrical table below.
Region Voltage
(V)
208
USA
240
208
Canada
240
Use a dedicated circuit breaker for the oven. The maximum distance between the right
side of the oven and the electrical receptacle is 5 .
Properly size the circuit breaker and network cables.
·
·
The oven MUST be properly grounded. In the event of damage due to improper
grounding to third par es and/or to the equipment, the will be held responsible and
will characterized as negligence due to the non-compliance with the standards.
There is an equipoten al point on the rear panel of the oven.
·
Note: The equipment has an interconnect connector for other equipment. This connector is
intended to keep several devices with the same electrical potential. Not necessarily the
grounding of a local connection. This connector on the rear of the device is identified by the
symbol on the right:
16
Freq.
Power
Phases
(Hz)
(kW)
6.2
Single
60
7.2
6.2
Single
60
7.2
Exhaust
Outlets
Power
Cable
INSTALLATION AND OPERATION MANUAL
Circuit
Breaker
Cable
(A)
NEMA
32
3x10AWG
6-30
NEMA
32
3x10AWG
6-30
3"
(76 mm)
Socket
Maximum
Distance
5
(1.5m)
Circuit
Breaker
Air Inlet