Saving the Adjustment Data

Fine Adjustment for Each Input Signal
Memory structure
98
(EN)
Adjustments
The memory structure of this projector consists of three memory blocks
and a normal adjustment data block.
Factory data
block
Save as the
service
data.
Service data
block
Factory data block: The seven basic adjustment data for different types of
signals shown in the table on page 99 (EN) are preset at the factory.
The adjustment data in this block connot be changed.
Service data block: The seven basic adjustment data for different types of
signals shown in the table on page 99 (EN) are preset at the factory.
The data saved in the user data block can be saved as the service data.
User data block: The seven basic adjustment data for different types of
signals shown in the table on page 99 (EN) are preset at the factory.
When a new signal is input, the data that has the nearest frequency is
automatically selected from among the seven basic data and the
existing data saved as input memory and loaded. If any of the data for
the signal is adjusted, the data is saved as an input memory in one of
the memory numbers 00 to 49. (If no data is adjusted, it is not saved.)
The adjustment data for each input signal, if any one of the signal input
conditions—vertical or horizontal frequency, type of sync signal, type
of input signal and input connector—is different, is saved in different
memory number as an individual input memory.
The memory number of the loaded data and that of the saved data are
displayed as "INPUT MEMORY No." on the INPUT INFO menu.
If the same signal has already been input, the same memory number
appears on two rows.
f H : 3 1 . 4 K H z
INPUT
SELECT
f V : 5 9 . 9 H z
H / C - S Y N C : P O S
PIC
CTRL
V - S Y N C : P O S
S o n G : N E G
INPUT
SETTING
I N P U T S I G N A L : R G B
SET
SETTING
I N P U T M E M O R Y N o . 0 2
INPUT
INFO.
SET:
SEL:
Normal adjustment data block: The data during adjustment is
temporarily saved in this block. When you press the ENTER or
MEMORY key after adjustment, the adjustment data is stored in the
user data block.
Load
User data block
Save
I N P U T - A
Memory number of the loaded data
n
N o . 1 1
ENTER
EXIT: MENU
Memory number of the saved data
Normal