Replacing The Lamp And The Air Filter And Cleaning The Ventilation Holes (Intake) - Sony VPL-GH10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Replacing the Lamp
and the Air Filter and
Cleaning the
Ventilation Holes
(Intake)
Tools you need to get started:
• Projector Lamp LMP-H201 (Optional)
• Standard Phillips screwdriver
• Cloth (for scratch protection)
The lamp used for the light source has a
certain lifespan. When the lamp dims, the
color balance of the picture becomes strange,
or "Please replace the Lamp/Filter." appears
on the screen, the lamp may be exhausted.
Replace the lamp with a new one (not
supplied)
without delay.
Use an LMP-H201 Projector Lamp as the
replacement lamp.
The air filter is supplied with the LMP-H201
Projector Lamp. When you replace the lamp,
it is also time to replace the air filter.
Whenever you replace the lamp, be sure to
replace the air filter with a new one. Also
clean the ventilation holes (intake).
Note
When "Status" is set to "All Off" in the Setup
menu, the message does not appear. (1
page 46)
Cautions
• The lamp remains hot after the projector is
turned off with the ?/1 (ON/STANDBY)
switch. If you touch the lamp, you may burn
your fingers. When you replace the lamp,
wait for at least 1 hour for the lamp to cool.
• Do not touch the glass surface of the
replacement lamp. If you touch it, wipe off
the fingerprints with a soft cloth.
• Pay special attention to replacing the lamp
when the projector is installed on the ceiling.
• When removing the lamp unit, make sure it
remains horizontal, then pull straight up. Do
not tilt the lamp unit. If you pull out the lamp
unit while tilted and if the lamp breaks, the
pieces may scatter, causing injury.
• When you remove the air filter, be careful
not to let any dust fall into the projector.
• Replacing the air filter is crucial to maintain
the good performance of the projector or to
prevent malfunction to it. When a warning
message for replacing the air filter appears,
replace the air filter immediately.
If "Status" is set to "All Off," the message
does not appear. (1 page 46)
1
Turn off the projector and unplug
the AC power cord.
2
When setting the projector on a
flat surface such as a desk etc.,
put a cloth to prevent the surface
from being scratched. Reverse
the projector as illustrated, then
place it on the cloth.
Notes
• When the lamp is damaged the broken
pieces of the lamp may become
scattered, if you do not reverse the
projector. This may cause injury.
• Be sure that the projector is placed on a
stable surface.
61