Type 3270, 3275
Technicaldata
6.5
electrical data
electrical data
type 3270
Connections
circular plug-in con-
nector
M12 x 1, 8-pole
Supply voltage
24 V DC ±10 % -
residual ripple < 10 %
Power
max. 8 W
consumption
Standby power
approx. 1 W
consumption
Actuating time
approx. ca. 2.5 s, for
(0...100 %)
setting "Valve actuating
speed normal"
Binary input
0...5 V = log „0",
(set-point value
10...30 V = log „1"
input)
Binary output
active, max. 100 mA
current limitation, PNP,
switching voltage =
U
-1 V, short-circuit
supply
proof
Limit switch
contactless end
position detection
All manuals and user guides at all-guides.com
type 3275
circular plug-in con-
6.5.1 Derating
nector
M12 x 1, 8-pole
The maximum duty cycle of the valve depends on the maximum
ambient temperatures and the current required by the stepper motor.
24 V DC ±10 % -
The derating curve can be used to indicate the maximum duty cycle
residual ripple < 10 %
permissible at the corresponding ambient temperature. By switching on
max. 12 W
the low power function a higher duty cycle can be achieved (Warning:
during low power function, max medium pressure is reduced; if violated
approx. 1 W
Valve will not move or malfunction).
approx. 4 s, for setting
"Valve actuating speed
normal"
0...5 V = log „0",
10...30 V = log „1"
active, max. 100 mA
current limitation, PNP,
switching voltage =
U
-1 V, short-circuit
supply
proof
contactless end
position detection
Fig. 3:
Duty cycle
as per EN 60034-1: S3
50%, depending on the
operating conditions.
Observe derating curve.
Setting options are described in the operating instruction
under:
www.burkert.com.
100
90
80
70
60
50
40
30
20
10
5 10
15 20
25 30 35 40 45 50 55 60 65 70
max. ambient temperature [°c]
Derating curve
english
as per EN 60034-1: S3
50%, depending on the
operating conditions.
Observe derating curve.
Normal operation
Energy save
function
9