3.4 - USE OF THE APPLIANCE
Work as follows in order to use the appliance.
To prevent possible damages to the compressor, each start is delayed by 3 minutes with
respect to the last switching off.
3.4.a - Preliminary operations
•
Place the appliance on a stable and not inclined base, at at least 30 cm. from the wall
or from any other object, in order to ensure the correct air circulation. Place it on a
water-resistant surface since the possible water leakage could damage furniture or
the floor.
•
Do not place the appliance directly on carpets, towels, blankets or other absorbent
surfaces.
•
Insert the plug in the power socket; the appliance emits a "beep", on the display
appears the icon
Before electrically connecting the appliance, make sure the plate data correspond to
those of the electricity distribution network.
3.4.b - Appliance switching on/off
a. The appliance can be switched ON or OFF for short periods by pressing B1 on the remote control or
SW1 on the control panel (if the appliance is switched off for a long period then it should be deactivated
by removing the plug from the mains supply.
b. The corresponding LED L2 lights up to indicate that the appliance is switched off.
c. In this condition, press B1 again on the remote control (or SW1 on the control panel) to restore all the
formerly selected functions.
When the appliance is OFF all the working timers are 'reset'.
3.5 - VENTILATION MODE (FAN)
a. When this operating mode is used the appliance has no effect on the temperature or humidity of the
environment, it merely circulates the air.
b. This mode can be selected by pressing B3 or SW2 until when the fan only symbol ( ) is activated on the
display of the control panel, while the symbol D6 appears on the remote controller display.
c. In this operating mode the internal fan is always on and the required fan speed can be selected at any
time by pressing key B3 (only from the remote control) (symbol D7 on the remote control).
3.6 - COOLING MODE (COOL)
a. In this mode the appliance cools and dehumidifies the environment.
This mode can be selected by pressing B2 or SW2 until the cooling only symbol
(
/ D3) is activated on the remote control and on the control panel display.
b. The internal fan is always on at automatic speed or (only from the remote control) at the selected speed.
c. The temperature set-point (Tset) can be adjusted from 17°C to 30°C (from 62 F to 86 F if present) in
1°C steps by means of B11 or SW3/SW4, and its value is shown both on remote and local interfaces.
d. Three minutes (maximum) after the activation of this operating mode the compressor starts and the ap-
pliance starts to distribute cold air.
3.7 - DEHUMIDIFICATION MODE (DRY)
a. This mode can be selected by pressing B2 or SW2 until the dehumidification only symbol ( / D4) is ac-
tivated on the remote control and on the control panel display.
and the environment temperature in °C.
EN - 15
DOLCECLIMA COMPACT M