Télécharger Imprimer la page

Amana ARG3600 Serie Mode D'emploi page 13

Publicité

Les langues disponibles

Les langues disponibles

Removal and Replacement of Range
1. Unplug range cord.
2. Turn off gas valve and disconnect gas supply.
3. Remove range and place aside.
4. Remove anti-tip bracket and reinstall anti-tip bracket
into new location using instructions provided with
bracket.
5. To reinstall range, follow instructions in Installation
section of this manual.
• Do not reuse a flexible connector after moving
appliance.
Place Grates and Burner Caps
Place burner cap on burner base and grate on rangetop.
A
B
C
A—Burner grate
B—Burner cap
C—Burner base
Place Grates and Burner Caps
Pegs in the burner base fit into recess in underside of
burner cap. To make sure cap is properly aligned and
leveled, move burner cap around on burner base. Burner
cap must be correctly seated on burner base for proper
operation of burner.
All manuals and user guides at all-guides.com
13
Make sure proper cap size is on each burner base.
Burner does not burn properly if wrong size burner cap is
placed on burner base.
Not centered
Burner Caps
Test and Adjust Surface Burner Flame
WARNING
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Turn on burner. See Operating Surface Burners section
for burner operating instructions. Surface burner should
ignite within 4 seconds. Properly adjusted surface burner
flames are clean and blue with a distinct inner cone
approximately ¼ inch to ½ inch long. Some yellow flame
is normal when burning LP/Propane.
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame does not hold its shape, increase
airflow to burner.
Burner
A—¼ inch to ½ inch long
Surface Burner Flame
Correct
Too small
Too large
A