11.9.
MAINTENANCE REVIEW
It is also advisable to check and clean at least once a year, all the ash registers in the boiler.
Your boiler has a preventive maintenance notice established at 1200 hours of operation, which will remind you MANDATORY of the need to clean the
EN
reservoirs of your boiler as soon as possible. These operations should be done exclusively by an authorised technician.
This message is not an alarm, but a reminder or warning. Therefore you will be able to use your boiler meanwhile this message is displayed but you
have to prevent the immediate cleaning of your boiler.
Please, bear in mind that depending on fuel and usage patterns the boiler could need to be cleaned before the1200 hours are completed or possibly
after this. This depends on the quality of the fuel used, the smoke installation, and the proper regulation of the boiler.
In the following table (also pasted on your boiler in the fuel tank cover) you can check the frequency of the maintenance tasks and who must do them.
CLEANING TASKS
Remove the burner from the combustion chamber and clean out the holes with the use of the poker provided. Remove the
ash using an ash vacuum-cleaner.
Vacuum the ash deposited in the burner compartment.
Empty the ash pan and vacuum the ash compartment when necessary.
Vacuum the bottom of the pellet tank before refill or when necessary.
Clean the insides of the combustion chamber descale the walls with correct brush and vacuum cleaner.
Clean the smoke extractor fan, the whole combustion chamber, pellet tank, replace seals, consumables and silicon as
necessary smoke ducts, ash reservoirs...etc
Check all the electronic components (electronic board, display...)
Check all the electrical components (igniter, smoke extractor fan, circulator pump, etc.).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
11:24
Wed 11 September
21º
Service
2
1
64
Crono
Disabled
Er.01
65º C
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
HYDROBOREAL