Electrical protection
•
The boiler is protected against abrupt electricity oscillations through a general fuse placed in the switch placed in the rear part. (4A250V
EN
Retarded).
Smoke outlet protection
included in the warranty unless the authorised technician can demonstrate a faulty component.
Water overheating protection (90ºC)
•
If the water temperature inside the boiler circuit reaches between near about 90ºC, the fuel loading is cut by
the water overheat safety sensor. If the temperature gauge is activated, restart needs to be done manually by an
authorised technician.
The replacement of the 90ºC water overheat safety sensor is not included in the warranty unless theauthorised
technician can demonstrate a faulty component to the satisfaction of Boreal's technical centre.
Flow Sensor
feeding fuel and ultimately close down and stop. If the pressure inside the heating system exceeds 2.5 bars, the
display will show the alarms "Er09 and Er10". To reset the safety device press button
least, 3 seconds.
Warning: the presence of air in the heating circuit can provoke activation of the system water pressure
transducer. If the sensor trigger and ceases to feed fuel to the machine, the alarms related to the lack of fuel may activate.
In order to get a proper performance of the product, the ideal pressure of the installation should be set at, approximately, 1.0-1.4 bars when
the installation is cold. Furthermore, it is necessary to ensure the absence of air in the heating system. Boreal advises to have an adequate air
purged circuit within the installation. The operation of air purging inside the installation is not included in the warranty.
•
Fuel capacity sensor
Your boiler has a capacitative sensor to detect the combustible level in the hopper. In case the combustible is below a determinate level, during a
determinate time, the display will show the message "Er18" (Low combustible) and the message NORMAL, running the boiler in a normal way, after this
time, the boiler will show alarm "Er18" and will start automatically in "final cleaning". To deactivate this alarm, it is necessary press the button
3 seconds, and the boiler will change to stop mode.
To initiate a new start, it is necessary refill the combustible hopper before we switch on again the boiler
any alarm, but it will not allow you to switch on.
In the case of have purchase the optional annexed tank for a greater fuel capacity, when the capacity sensor detects a possible fuel shortage, it
will activate the tank motor, to automatically refill fuel into the hopper of the boiler for a set time.
Installation Safety Devices
•
It is COMPULSORY to have a system pressure gauge to visualize the water pressure of the heating circuit.
The closed expansion vessel of the installation should have a dimension between 4 and 6% of the total volume of the installation. The
integral boiler mounted closed expansion vessel is likely to be inadequate for the central heating circuit..
5. FUELS
In order to guarantee a proper combustion, it is necessary to use quality combustible materials that meet the stated standards.. The use of
combustible materials in which breach the specifications mentioned below implies the cancellation of the warranty and the manufacturer's
responsibility for the product.
If you use combustible materials according to the present specification, we guarantee an impeccable working and good performance values of the
installation. In the event of not knowing a distributor able to supply materials meeting these criteria, we would kindly inform you about the distributors that
you may be interested in.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Smoke outlet protection
•
The electronic pressure switch blocks the operation of the boiler in the event of an abrupt change of the
pressure inside the combustion chamber (door opening, breakdown of the smoke extraction motor, etc). If
this happens, the machine will go into an alarm state.
Protection in the event of high temperature inside of
•
the hopper the fuel storage tank (80ºC)
In the event that the inside of the pellet tank overheats this device stops the operation
of the machine. The restart needs to be done manually by an authorised technician.
The replacement of the 80ºC thermal protection sensor on the pellet hopper is not
Flow sensor (Smart Control)
•
Your boiler has a flow sensor placed inside the inlet of the primary air supply pipe that
detects the proper circulation of fresh air to the combustion chamber and the smoke exhaust. In the event that insufficient air
is supplied (due to incorrect smoke outlet or improper air intake), the sensor sends a "cut out" signal.
The SMART CONTROL ensures a constant combustion by controlling automatically the chimney draw or draught
calculated from the flue characteristics (curves, length, diameter, etc) and the environmental conditions (wind, humidity,
atmospheric pressure, etc).
System water pressure transducer
•
If the pressure of the heating system is lower than 0.4 bars, the boiler will cease
on the display for, at
36
Electrical
protection
Protection temperature hopper
Water
overheating
protection
Transducer
at least
, otherway your boiler will not show
HYDROBOREAL