9.7.2.
BOILER RUNNING
Once smokes temperature reach the set up the boiler considers it is working, then will switch to "stabilization" during a few minutes before ending the
lighting process.
Once the stabilization process is finalized the boiler is in mode "Run mode" represented by the normal working mode. The display will show the time,
date, working power, water temperature, thermostat temperature and winter/summer mode.
9.7.3.
WATER TEMPERATURE ADJUSTEMENT
This function is only available inside the user menu. Check the chapter 9.8.2.1.
9.7.4.
WORKING POWER ADJUSTEMENT
This function is only available inside the user menu. Check the chapter 9.8.1.1.
9.7.5.
ROOM TEMPERATURE REACHES THE REQUESTED VALUE BU THE USER
When room temperature reaches the requested value by the user, the boiler receives the order through an external thermostat connected to the boiler and
automatically start the switch of process, and will switch on automatically when room temperature in under the consigned temperature. This depends on
the thermostat hysteresis installed in your house.
9.7.6.
WATER THERMOSTAT REACHES THE REQUESTED VALUE BU THE USER
When the water temperature of the boiler reaches the requested value by the user, the boiler start mode "stand by", i.e. starts modulation lowing the
power to adequate to the selected temperature of the water and keep on working. In this case it is possible that your house do not reach the temperature
requested from the external thermostat because the water temperature value that you have fixed is low for your comfort temperature. We recommend
putting an enough temperature value (70-75º) to allow the boiler keep on working and reach your house comfort temperature.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS