9.8.4.5.
SUBMENU 4.4. WEEKEND PROGRAM
This submenu allows the selection of three possible hours of lighting on and three possible hours of lighting off of your boiler for the days Monday,
Tuesday, Wednesday, Thursday and Friday; and other three different possible hours of lighting on and off for Saturdays and Sundays. You can choose
only one slot of running, two or even three slots each day.
Time 1
Time 2
Time 3
9.8.5.
MENU 5. MANUAL AUGER LOAD
In the case the boiler during running on is out of combustible, alarm Er18 (low combustible) will
appear because your boiler has a capacitive sensor to detect the level of combustible in the hopper.
To deactivate this alarm it is necessary to press the key
will go to stopped mode.
To initiate a new start, it is necessary refill the combustible hopper before we switch on again the
boiler
, other way your boiler will not show any alarm, but it will not allow you to switch on.
However, when the boiler is stopped and cold and the door closed it is possible to do a pre-load
of pellets during a maximum time of 600 seconds to load the auger To start this load go to menu
"manual load" and after pressing key ON and confirm with key
start moving; you will see how the smoke extractor will start during the load as a security mode. To
stop this load press the line OFF and confirm with key
Do not forget before switching on the boiler proceed to totally empty the pellet burner to avoid a
dangerous situation.
9.9.
USER MENU 2
To access user menu 2 it is necessary push the botton
The next table describes briefly the structure of the user menu 2 in the boiler. The available options for the user are specified.
To select different menus it is necessary to push in each line (menu) and you will access to different available submenus. To modify the values we have
the keys
and
to increase and decrease and confirmation key
screen, or increase one menu level pushing the key
Menu
Keyboard set up
Display
System menu
9.9.1.
MENU 1. DISPLAY SET
9.9.1.1.
DATE AND HOUR
Establish the date and the hour. To do it we have to move in the different menus (hours, minutes,
year, month, date) and to modify the values we have to push the keys
decrease and confirmation key
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Week-end
Monday-Friday
00:00
00:00
00:00
00:00
00:00
00:00
at least during 3 seconds and the boiler
.
in the display.
.
Submenu 1
Date and hour
Language
Light contrast
Keyboard direction
Node list
.
Saturday-Sunday
Time 1
00:00
Time 2
00:00
Time 3
00:00
, the auger will automatically
. To exit from the menu it is necessary to push the key
Submenu 2
Value
Italian, English, German, French, Spanish and Portuguese
Value ( between 1 and 100)
Protected by password
Protected by password
and
to increase and
59
Wee-end
00:00
00:00
00:00
Manual Load
OFF
ON
and go to the main
Set time and date
11:41
27/05/2016
EN
HYDROBOREAL