Assembly instructions of the steel bottom piece
1.
You should introduce the piece through the window of the tank as you can see in the following picture.
2.
The piece should be placed in the position you can see in the following
picture, it will remain on the sides, front slope and pellet-loading pipe.
6. SAFETY RULES DURING INSTALLATION
The way of installing the boiler will affect the safety and the proper operation. For this reason, it is essential that the installation is carried out by qualified
installers who are trained to make an installation compliant with local safety and installation regulations.
European, national, regional, provincial and municipal regulations.
Flue installations or smoke evacuation systems T must be controlled before the installation with respect to the following:
•
Prohibitions relating to the installation.
•
Legal distances.
•
Limits established by the local administration rules or generals provisions of the relevant authorities.
•
Conventional limits derived from the owner's community rules or contracts.
Overall, the installation must comply with all the regulation applicable according to local, national and European laws.
If your equipment is not properly installed, it may cause serious damage.
Before the installation, carry out the next series of checks:
•
Make sure that the floor can sustain the weight of the equipment and make a proper thermal isolation in the case that the floor is made of
flammable material (wood) or a material that can be affected by a thermal shock (plaster , for example).
If the equipment is installed on a floor which is not completely refractory or inflammable such as parquet, carpet, etc, it is necessary to replace this
part or introduce a fire-resistant base so that it protrudes beyond the front of the boiler 30 cm. Example of materials include steel flooring, glass
base or any other type of fire-resistant material.
•
Make sure that there is proper ventilation in the place where it is installed (air intake).
•
Avoid the installation in places where there are collective ventilation pipes, hoods with or without extractor, B type gas equipments, heat pumps or
equipments that can influence the flue draught The chimney draw may not be good if they are used at the same time.
•
Make sure that the smoke duct and the pipes used for the chimney are suitable for the operation of the boiler.
•
Make sure that all the equipments have their own smoke duct. Do not use the same duct for several equipments.
•
We recommend that you call your fitter in order to check both the chimney as well as the air flow for the combustion.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
39
EN
HYDROBOREAL