Pilz PSEN op2 Série Manuel D'utilisation page 86

Barrière de sécurité à rayons infrarouges
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating Manual
Optoelectronic, mechanical, proximity sensors etc. can be used as
muting sensors, using a closed contact when the object requiring
detection is present.
The following configuration examples illustrate the application of the
muting function:
-
Application with four optoelectronic sensors:
\
L
B2
A2
B1
A1
PSEN
d1
d1
D
D :
Minimum distance for the muting sensors to maintain activation;
the length of the package is the key factor: D < L.
d
:
Distance required for the muting activation to be accepted; the
1
approach speed of the package is the key factor for this
distance:
d
[cm]= v[m/s] * 0.5[s] * 100
1max.
[cm] ≥ 0.1
d
1min.
The cable of the muting sensors must be laid in separate multicore
cables.
33
PSEN op 2/4 Series
Connection for the muting sensors:
24 Vcc
Receiver connector
CONTACT A1
v
Pin 3
CONTACT A2
MUTING 1
Pin 4
CONTACT B1
MUTING 2
CONTACT B2