PSEN op 2/4 Series
6.4.

Muting function

The muting function can be selected via DIP switches; it enables
the safety device to be suspended temporarily while material is
transported through the protected field (Fig. 22).
To comply with current regulations the safety device has two inputs
(muting 1 and muting 2) for activating the muting function.
The muting function is particularly appropriate where operating
conditions require an object to pass through the danger zone, but
not a person.
It is important to remember that the muting function represents a
forced situation for the whole system, and as such should be
applied with due care.