Partial Muting Function - Pilz PSEN op2 Série Manuel D'utilisation

Barrière de sécurité à rayons infrarouges
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PSEN op 2/4 Series

6.4.1. Partial muting function

Safety curtains in the PSEN op2/4 series have an
additional partial muting function, which permits the
blanking of selected zones within the protected field.
This function enables the blanking of up to 4 zones
(optical groups). The width of the blanking depends
on the height of the protected field (partial or total
muting) and the resolution of the respective safety
device.
Monitoring and blanking of the 4 zones enables a
range of configurations:
-
Blanking any one of the 4 individual zones (Zone A
only, Zone B only, Zone C only, Zone D only, see
diagram). The uppermost optic in Zone D will not
switch to partial muting but will maintain normal
operation,
as
it
is
responsible
synchronisation between the
receiver.
-
Blanking zone groups; in particular: Zone A+B;
Zone A+B+C; Zone A+B+C+D.
-
Blanking the whole of the protected field = total
muting.
The required configuration can be set using the DIP
switches on the receiver.
The following overview illustrates the configuration
options on the different safety light curtain models.
Operating Manual
for
optical
transmitter and
30

Publicité

Table des Matières
loading

Table des Matières