4. ELECTRICAL CONNECTIONS

All electrical connections to the transmitter and receiver are made via
an M12 connector, located on the bottom of both the units. The
receiver uses 8-core cable and the transmitter 4-core cable.
RECEIVER (RX):
OSSD1
OSSD2
6
7
0 V
1
+24 Vdc
= TEST/START
1 = white
2 = brown
= +24 Vdc
3 = green
= MUTING 1
4 = yellow
= MUTING 2
5 = grey
= OSSD1
6 = pink
= OSSD2
7 = blue
= 0 V
8 = red
= LAMP
TRANSMITTER (TX):
not assigned
2
0 V
3
= +24 Vdc
1 = brown
0 V
3 = blue
=
19
PSEN op 2/4 Series
5
4
3
2
+24 Vdc
8
+24 Vdc
+24 Vdc
1
not assigned
4