6. OPERATING MODE

6.1.

Selecting the operating mode via DIP switches

On the front of the receiver RX there
is a cover flap (Fig. 20), which is
easy to open using a screwdriver and
exposes a row of DIP switches used
to set the following configurations:
-
Manual / automatic start
-
Total muting function
-
Partial muting function
The device will not accept any
configuration changes during normal
operation. If it is necessary to change
the configuration, this can only be
achieved by resetting the device.
Particular care should therefore be taken when setting the DIP
switches.
6.2.

Standard configuration

The device is supplied with the following standard configuration:
-
Automatic start
-
Total muting activated
NOTE:
The muting function can only be activated if muting
inputs 1 and 2 and the muting lamps are connected
correctly.
Detailed information on these functions can be found
in Ch. 6.3 and 6.4.
25
PSEN op 2/4 Series
DIP switches
Fig. 20