Installation
Observe the following instructions when installing the supply lines:
• Also observe the installation instructions for the evaporator unit.
• The maximum cable length between the evaporator and compressor unit is:
– SP950T/SPX1200T: approx. 4.2 m
– SP950I: approx. 2.3 m
– SPX1200IC: approx. 2.1 m
• Avoid any narrow radii when routing and bending supply lines. Use a suitable
round object with a shim as a bending aid. A radius which is too narrow will
kink the refrigerant line, and this will prevent the auxiliary air conditioning unit
from operating.
➤ Shorten any supply line which is not needed by bending a curve.
➤ SP950C only: Insert the plug of the cable (power cable) into the mating
plug of the compressor unit (fig. a).
➤ SPX1200C only: Assemble the connection cable and corrugated piping as
shown (fig. 0 and fig. b).
➤ SP950C only: Insert the plug connection of the fan cable back together.
➤ Place the outer housing onto the compressor unit.
➤ SP950C only: Fasten the outer housing with the eight hexagon socket
screws (fig. c 2).
➤ SP950C only: Fasten the fan with the four hexagon bolts (fig. c 1).
➤ SPX1200C only: Fasten the outer housing with the six torx screws (fig. 0).
➤ Apply sealant (fig. e 1) to prevent any water from getting between the rear
wall of the truck and the clip.
I
NOTE
If you want to avoid damaging the rear wall of the truck (drilling a hole), you can
also apply the clip using a suitable adhesive.
Observe the instructions provided by the adhesive manufacturer.
➤ Use the supplied holders to fasten the connection line to the rear panel of the
truck (fig. e).
➤ Insert corrugated piping in the holder provided (fig. e 2).
➤ Put on the lid (fig. e 4).