Logic
Definition
Configuration of EXPI1
input on input-output
EXPI1
expansion board.
Configuration of EXPI2
on input-output
EXPI2
expansion board.
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
Traffic light pre-
TRAFFIC LIGHT
PREFLASHING
flashing
TRAFFIC LIGHT
Steadily lit red light
RED LAMP
ALWAYS ON
*
Only active on FW ≥ 1.08
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
associates the desired key with the 2nd radio channel command. Associates the desired key with the 2nd radio channel command. If no output
add 2ch
is configured as 2nd Radio Channel Output, the 2nd radio channel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
28 -
SIRIO CBA 230 INV
INSTALLATION MANUAL
Cross out
Default
setting
used
11
1
12
1-2
13
14
15
16
17
18
input
0
1-3
11*
12*
11
4-5
11
6-7
12*
0
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
*
movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
*
movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is
*
switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
*
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/
*
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
*
automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing
*
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening
*
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
0
Output configured as 2
Radio Channel.
nd
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
Output configured as anti-tampering
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
0
Red lights off when gate closed.
1
Red lights on when gate closed.
Optional extras