en
|
Operation
®
3.2.2
Dräger Polytron
Repeater WirelessHART
®
The Dräger Polytron
Repeater WirelessHART
®
Polytron
6100 EC WLwithout measuring function.
3.3
Sensors
The gas detector is intended for use with the DrägerSensor
(electrochemical). Select the sensor according to the target gas to be
measured.
3.4
Interfaces
Interface
®
WirelessHART
network
®
Bluetooth
3.5
Intended use
®
3.5.1
Dräger Polytron
6100 EC WL
The gas detector is used in conjunction with the built-in DrägerSensor
monitoring toxic gases and oxygen.
®
3.5.2
Dräger Polytron
Repeater WirelessHART
The repeater is used to forward data from other WirelessHART
participants.
3.6
Approvals
The approvals are shown on the name plate. A copy of the name plate and the
declaration of conformity can be found in the document "Notes on Approval"
(order no. 93 00 532).
38
®
®
is a version of the Dräger
®
EC
Connection via the network (see "Network
integration", page 43).
®
Connection to a Windows
terminal device
®
in the field (see "Bluetooth
interface",
page 39).
®
®
®
network
Instructions for use
|
Dräger Polytron
4
Operation
Task
Activate the Blue-
®
tooth
interface.
Reset the gas
detector.
Reset the battery
counter.
If the gas detector is operated by a battery, do not remove the battery box
during configuration.
4.1
LED display
Symbol
LED display
Green LED
flashes once
for
Yellow LED
flashes once
Yellow LED lights
up continuously
®
6100 EC WL, Dräger Polytron
®
®
Bluetooth
WirelessHART
(PolySoft)
network
(DD/DTM)
-
Meaning
Gas detector is switched on
Alerts (e.g., low battery or sensor warm-up
phase active) or maintenance mode
Error
®
Repeater WirelessHART
Magnetic pen
®