Only put beverages inside the appliance after it has reached the operating temperature set on
the control unit (see paragraph 5.4 - Operation);
Beverages should only be placed inside the appliance if they are packaged or closed in bottles,
cans, or similar suitable food-grade containers.
Each support rack has a maximum capacity of 12 kg.
5.4 Operation
The appliance is operated by means of the digital control unit, which is used to set the desired op-
erating temperature.
See Pic.1 (Section 8 - Images) for more details about the control panel.
The user may carry out the following operations:
Switch on/off (see Pic.1 and Pic.3 - Section 8)
To turn on the appliance, connect the power plug: the current temperature inside the refrigerated
cell will appear on the display. In the case of a power failure, the compressor will restart approxi-
mately 3 minutes after the power supply has been restored in order to avoid damaging the appli-
ance by switching it on and off multiple times. It is possible to turn on or turn off the internal LED
light by pressing the L
To shut off the appliance disconnect the plug from the electrical socket. Wait at least 10 seconds
after disconnecting the plug before connecting the appliance to the power supply line again.
Temperature setting (set point)
Press the S
button for approximately 3 seconds, until the display shows "St" and the S
ET
turn on. Press again the S
keys to raise or lower the set point temperature. Press once the S
Press the R
key, or do not press any key for more than 30 seconds to exit the adjustment menu
ST
and go back to the current temperature visualisation. The temperature setting can be read by press-
ing the S
button once.
ET
When running, the appliance will cool the cell until the currently set operating tem-
perature is reached. Once the set operating temperature is reached, the electronic
control unit will turn off the cooling unit until the temperature detected by the
probe rises by about 4-5 degrees. When this happens, the control unit will turn on
the cooling unit to lower the temperature until it returns to the set operating tem-
perature. This "on-off" mechanism is perfectly normal and is common in all refrig-
eration equipment such as refrigerated bars, cabinets, display cases, etc.
Please note that the temperature shown on the control unit display refers to the
air temperature (very susceptible to temperature changes due to the opening of
the door) and not to the temperature at the core of the appliance, which is much
more constant over time.
Error messages displayed on the control unit:
MESSAGE
E1
If one or more error codes are displayed, write them down, turn off the appliance then turn it back
on after 3-4 minutes. If one or more of the codes are again displayed, contact the dealer to request
technical support and inform them of the error codes.
TRANSLATION OF THE ITALIAN ORIGINAL INSTRUCTIONS
switch inside the refrigerated cell (Pic.1 - Section 8).
IGHT
button. The display will show the current set point. Use the U
ET
ERROR DESCRIPTION
Faulty thermostat probe
key to save the adjustment.
ET
EFFECT
The temperature is no longer
being adjusted correctly
light will
ET
and D
P
OWN
SOLUTION
Contact the dealer
- 27 -