6.2.
Structure
Position measuring system with LED's
Electronics module
(24VDC- or AS-i-
Design with service
interface, connection
terminals, DIP, Teach-
In-buttons)
Mechanical
manual control
at solenoid
valves (red
levers)
Electrical
connections
(Cable
glands)
Sealing lug
Locking/(shoulder) screws
as protection against pulling
off from the hub fl ange
english
12
Oil content:
max. 25 mg/m
(quality class 5)
Temperature range
of compressed air:
-10 to +50 °C
Pressure range:
2.5 to 8 bar
Air rate of solenoid
valve:
110 I
/min (for de-/aeration, ventilation)
N
(110 I
/min - supplied state
N
200 I
/min - maximum typical fl ow-rate)
N
(Q
value according to defi nition for
Nn
pressure drop from 7 to 6 bar absolute
at +20 °C)
Connections:
Intake and exhaust air connection G1/4
Working connections
7.4.
Position Measuring System Data
Stroke range:
0 ... 80 mm (measuring range)
 0.1 mm
Resolution:
Total fault:
± 0.5 mm - when using a target as
mentioned in the manual
7.5.
Electrical Data
see chapter 9. 24 V DC - Design or 10. AS-I - Design or
11. DeviceNet- Design or 12. 120 V AC - Design .
english
14
All manuals and user guides at all-guides.com
Flow restriction
screw(s) of
solenoid valves
Pneumatic
connections
3
G1/8
7.
TECHNICAL DATA
7.1.
Operating Conditions
Ambient temperature:
-10 ... +55 °C
Protection class: IP65 / IP67 according to EN 60529 or
IP69K according to IEC 40050-9
7.2.
Mechanical Data
Dimensions:
see data sheet
Housing material:
outside:
inside:
Sealing material:
outside:
inside:
7.3.
Pneumatic Data
Control medium:
Oil-free and dry air, neutral gases,
Quality classes in accordance with
DIN ISO 8573-1 (5 µm fi lter
recommended)
Dust content:
max. particle size 40 µm,
(quality class 5)
max. particle density 10 mg/m
Water content:
max. pressure dew point -20 °C or
(quality class 3)
min. 10 °C below the lowest
operating temperature
8.
ASSEMBLY / INSTALLATION
DANGER!
Risk of injury from high pressure in the equipment!
Before loosening pneumatic lines and valves, turn off
the pressure and vent the lines.
WARNING!
Risk of injury due to electrical shock!
Before reaching into the system (except for the
Teach-In procedure in a non-explosive atmosphere)
switch off the power supply and secure it to prevent
restarting!
Observe applicable accident prevention and safety
regulations for electrical equipment!
Risk of injury from improper installation!
Installation may be carried out by authorized techni-
cians only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
Secure system from unintentional activation.
Following assembly, ensure a controlled restart.
Type 8681
PA, PP, PPO, VA
ABS, PA, PMMA
CR, EPDM
EPDM, FKM, NBR
3
english
13
english
15