Télécharger Imprimer la page

Stalgast 803021 Notice D'instruction page 36

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Error code
E2 LO
temperature of probe T2 is too low (below 0 °C) (or an open circuit in the probe)
E2 HI
temperature of probe T2 is too high (above 110 °C) (or a short circuit in the probe)
E3 LO
temperature of probe T3 is too low (below 0 °C) (or an open circuit in the probe)
E3 HI
temperature of probe T3 is too high (above 110 °C) (or a short circuit in the probe)
E4
Et
E1
E2
safety temperature exceeded – error displayed after the completion of emergency
4. Start-up of the device
Turn on the switch located on the wall, open the dishwasher door, place the overflow plug in the ap-
propriate place (fig. 8) and close the door of the device. Press the
and the boiler are filled with water, the boiler heating element will start operation. After the heating of
water in the boiler is completed, the dishwasher chamber water heating cycle will begin. Insert the
basket into the device chamber and wait until the water in the chamber reaches the set temperature.
Before starting the wash cycle, it is necessary to select the program. The wash cycle is activated au-
tomatically by opening and closing the dishwasher door. If the door is opened during the wash cycle,
the program stops automatically. After the door is closed, the program continues the wash cycle. The
completion of the wash cycle program is indicated by a sound signal from the control board. Remove
the basket from the device chamber.
Water for washing
Water for rinsing/sanitizing
5. Emptying of the tank in models equipped with a drain pump
Turn the device off by pressing the
flow plug and close the door. Turn the drain pump on using the
process proceeds automatically until the tank is completely emptied of water. In order to reactivate the
device, put the overflow plug back in its place, close the door and press the On/Off switch. However, if
the device will not be used any more, turn the main switch off.
6. Emptying of the tank in models not equipped with a drain pump
Turn the device off by pressing the
flow plug and wait until the water is drained off completely from the tank. Put the overflow plug back in its
place, close the door of the device.
Do not turn the device off when the water is still in the tank. Before turning the device off, always empty
the tank of water. In the event the device will no longer be used, after the completion of the above and the pos-
sible initiation of a regeneration cycle, it is necessary to turn the device off by pressing the switch. The main
switch should then be turned off and the water valve should be closed.
power outage during the operation of the dishwasher
temperature difference between probe T1 and T2 is too high (>30 °C)
switch , then open the door of the device, remove the over-
the switch , then open the door of the device, remove the over-
Error description
boiler overheating
rinsing
60-65 °C (140-149 °F)
82-90 °C (181-194 °F)
- 36 -
switch button . After the tank
button. The draining