The electrodes must be installed for operation on the control unit in accordance
with the diagram below.
4.2 pH setpoint: [7.2]
The setpoint is used to set the desired pH value of the pool water. In the event that the
setpoint is undercut or exceeded, the dosing pump will be activated in accordance with
the settings. The basic setting ex works is designed for dosing pH reducing chemicals.
4.3 pH p-band: [-1.0]
•
Dosing direction for pH value:
With a negative p band [-1.00], if the setpoint is exceeded, the dosing pump is
activated. When using this setting, pH-reducing chemicals are employed.
Since sodium hydroxide is a by-product of salt electrolysis, only pH-lowering
agents are dosed.
SN6 connection for
the pH electrode
SN6 connection for
the Rx electrode
Screw
connection
for
the
Rx
electrode
Screw connection
for
the
pH
electrode