Multiple errors will be alternated on the display.
The dosing is automatically continued by Flow and Level after the elimination
of any problems.
The resetting of the Limit error message is carried out using the OK button.
The switch-on delay follows. This may also be cancelled using OK.
➢ ! – Additional display in temperature range with temperatures < 5°C
➢ Min. alarm and Max. alarm for pH and Redox
see section 4.4 + 4.5 for pH and 5.4 + 5.5 for Redox
Other error messages at a glance:
➢ "LOW COND. (low conductivity) is displayed in case of: too low salt content; low
temperature (at <15°C the mode with reduced efficiency is tried first); used
electrodes! (especially if temperature and salinity potentially "match"); contact
problems to the electrolysis cell (oxidation in the connector or damage to the
cable).
➢ "GAS" (gas detector in electrolysis cell has responded) is displayed in case of:
Gas in electrolytic cell; contact problems with the electrolytic cell (oxidation in
the connector or damage to the cable).
➢ SHORT CELL" is displayed if:
Short circuit between the main electrodes of the electrolysis cell (or cable
damage); extremely high salt content.
➢ SHORT GAS" (short-circuit gas detector) is displayed in case of:
Short circuit between gas detector electrode and one of the main electrodes (or
cable damage).
In the event of these faults, a new start attempt is made after approx 25 seconds
will be attempted.
If other error messages like the ones described above appear, please contact
your specialist dealer/swimming pool builder.