Part I - Table of contents:
1
Overview of control unit .................................................................... 38
2
Displays in operating mode ................................................................ 39
2.1 Error messages ........................................................................... 39
3
Menu mode/changing parameters ....................................................... 40
3.1 Stop controllers ........................................................................... 42
3.2 Hand control ............................................................................... 43
3.3 System settings ........................................................................... 43
3.3.1
Date ................................................................................... 43
3.3.2
Time ................................................................................... 43
3.3.3
Language ............................................................................ 43
3.4 Configuration .............................................................................. 43
3.5 IDS – Intelligent Dosing System .................................................... 43
3.6 Delay time .................................................................................. 44
3.7 Limit pH (120 min) ....................................................................... 44
3.8 Limit disinfection (0min) ............................................................... 44
4
pH settings ...................................................................................... 44
4.1 Calibration probe ......................................................................... 44
4.2 pH setpoint: [7.2] ........................................................................ 47
4.3 pH p-band: [-1.0] ........................................................................ 47
4.4 Minimum alarm (↑): [6.80]............................................................ 48
4.5 Maximum alarm (↑): [7.60] ........................................................... 48
5
Rx settings ...................................................................................... 48
5.1 Test probe .................................................................................. 48
5.2 Rx setpoint: [650 mV] .................................................................. 48
5.3 Rx p band: [20 mV] ..................................................................... 49
5.4 Minimum alarm (↑): [550 mV] ....................................................... 49
5.5 Maximum alarm (↑): [750 mV] ...................................................... 49
6
Test mode ....................................................................................... 49
7
WLAN set-up .................................................................................... 50
7.1 Web set-up mode ........................................................................ 50
7.2 Manual set-up - Manual entry screen for the WLAN password ............ 51
7.3 IP address................................................................................... 51
7.4 WLAN SSID ................................................................................. 51
7.5 WLAN password ........................................................................... 51
7.6 MAC address ............................................................................... 51
7.7 VPN connection to WLAN router ..................................................... 51
8
EC - Declaration of conformity ............................................................ 52
37