Type 8645
EXPANDING A VALVE TERMINAL
Fig. 7:
Checking O-rings and seals
Fig. 8:
Attaching additional module
Fig. 9:
Securing added modules
All manuals and user guides at all-guides.com
Step 5:
→
→
Step 6:
→
Ensure that the seals and plug-in contacts are not
damaged.
Step 7:
→
→
→
Before adding new modules, first check that the
O-rings and seals are correctly positioned.
Then grease the O-rings and seals, both on
the pneumatic channels and on the electrical
connections.
Connect additional module to the valve terminal
by pushing it on parallel and pressing it into
position.
Connect added modules to the existing valve
terminal by pressing and then turning the three
locking pins clockwise through 90°.
The depression of the locking pins can be facili-
tated by pressing the module onto the existing
valve terminal. The slot is vertical.
Then attach the added modules to the wall or top
hat rail.
english
9