Type 8645
EXPANDING A VALVE TERMINAL
3.1.
Expansion by additional function modules
Fig. 1:
Attaching the connecting bracket
NOTE!
Pulling on one side may damage the locking bracket!
Fig. 2:
Release locking pins
Fig. 3:
Supporting the snapping out of the locking pins
By applying gentle lateral pressure to the exposed side areas of the valve terminal in the vicinity of the cor-
responding locking pins, they can be supported as they are snapped out.
NOTE!
If the modules are removed without disengaging the locking pins, the modules may be damaged!
All manuals and user guides at all-guides.com
Step 1:
To expand the FreeLINE valve terminal, first detach
the blue connecting bracket.
→
1
Step 2:
→
In the released position the slots in the locking pins
are horizontal. The locking pins project over the
contact surface of the connecting bracket.
Using the two projecting lugs, pull up the blue
connecting bracket 1 parallel and remove.
Using a screwdriver, release the 3 locking pins by
turning them anti-clockwise through 90°.