EXPANDING A VALVE TERMINAL
Fig. 14:
Aid when releasing the locking pins
If the locking pins cannot be released, they can be released from the back of the modules using a
screwdriver.
To do this, press a small screwdriver blade onto the corresponding locking pin on the respective module
until the locking pin disengages audibly.
3.2.
Replacing the communications module
Fig. 15:
Attaching the connecting bracket
NOTE!
Pulling on one side may damage the connecting bracket!
All manuals and user guides at all-guides.com
Step 1:
To replace the communications module, first detach
the blue connecting bracket.
Using the two projecting lugs, pull up blue con-
necting bracket parallel and remove from the
interface to the function modules.